LI Gang1, YUAN Yi-chao2, LIU Yu-zheng2 1.College of Electrical Engineering. CONCEPTUAL ANALYSIS ON STEAM-WATER INJECTOR APPLIED TO START-UP SYSTEM OF 600 MW SUPERCRITICAL UNIT[J]. Thermal power generation, 2009, 38(4): 61-64.
LI Gang1, YUAN Yi-chao2, LIU Yu-zheng2 1.College of Electrical Engineering. CONCEPTUAL ANALYSIS ON STEAM-WATER INJECTOR APPLIED TO START-UP SYSTEM OF 600 MW SUPERCRITICAL UNIT[J]. Thermal power generation, 2009, 38(4): 61-64.DOI:
The start-up system with recirculating pump for supercritical unit has such shortcomings as complex structure
high investment
and cavitation in recirculating pump.Therefore
a pressed steam-water injector is proposed to replace the recirculating pump. Numerical computation of output pressure based on the direct contact condensation model demonstrates that the new start-up system with pressed steam-water injector possesses not only the same functions of the original system
but also the advantages of simple structure
low investment
higher reliability
and cavitation-free.In the pressed steam-water injector
supersonic steam flow drives sub-cooled water and condenses in it
the condensation changes the mixture temperature to form a shock wave for improving water discharge pressure.The new start-up system takes high-speed steam flow formed by drainage vaporization as its source power.