SHI Jian-liang, WANG Xin-yu North United Electric Power Co.. ANALYSIS AND TREATMENT OF VIBRATION FOR TURBOGENERATOR UNITS DURING TRIAL OPERATION[J]. Thermal power generation, 2009, 38(4): 54-57.
SHI Jian-liang, WANG Xin-yu North United Electric Power Co.. ANALYSIS AND TREATMENT OF VIBRATION FOR TURBOGENERATOR UNITS DURING TRIAL OPERATION[J]. Thermal power generation, 2009, 38(4): 54-57.DOI:
Some sub-critical 300 MW and 600 MW turbogenerator units
which were put into operation in recent years by North United Electric Power Corporation
Ltd.
have undergone vibration problems.These vibration problems include over-vibration of low-pressure rotor bearing chock
sudden low-frequency vibration of No.1 and No.2 bearings due to the vibration of high-or medium-pressure rotor excited by steam under heavy load
and vibration measuring error because of defective insulation of generator bearing chocks.This paper describes the features of the vibrations in the units
analyzes the causes of vibration
and summarizes the field treatments for reducing these vibrations.