HAN BoYuedian Jinghai Power Generation Co Ltd. ANALYSIS OF OVER-TEMPERATURE ON THE PLATEN SUPERHEATER OF ONCE-THROUGH BOILER FOR SUPERCRITICAL 600 MW UNIT[J]. Thermal power generation, 2009, 38(7): 60-61.
HAN BoYuedian Jinghai Power Generation Co Ltd. ANALYSIS OF OVER-TEMPERATURE ON THE PLATEN SUPERHEATER OF ONCE-THROUGH BOILER FOR SUPERCRITICAL 600 MW UNIT[J]. Thermal power generation, 2009, 38(7): 60-61.DOI:
超临界600MW机组直流锅炉屏式过热器超温问题分析及治理
摘要
某电厂2号超临界600 MW机组直流锅炉检修后屏式过热器(屏过)A侧出口频繁出现超温现象。分析认为
一次风速偏大
炉内火焰中心偏高
炉膛左右两侧火焰温度存在偏差
实际燃用煤种比设计煤种灰分高
A、B两侧引风机出力不均
升负荷速率偏快等是造成屏过超温的原因。对此
采取了对锅炉燃烧进行优化
适当增加水冷壁的吹灰次数
并对断裂的A侧减温器喷管进行打磨修复等措施。实施后
A侧汽温可以控制在540℃以内
屏过出口超温问题得到了有效的控制。
Abstract
After repair of the once-through boiler for supercritical 600 MW unit no.2 in one power plant
over-temperature phenomenon frequently appears on the outlet at A side of platen superheater.It is believed from analysis that the causes of over-temperature may be as follows:the speed of primary air was somewhat larger
the flame centre in furnace was some what higher
the flame temperature at left and right side of furnace had deviation
the ash content of used coal sort was higher than that of designed coal sort
the output capacity of fans at A and B side wasn't uniform
the load was rapidly increased
etc..Regarding to these
some measures
such as optimization of combustion in the boiler
suitably increase the numbers of sootblowing to the water-wall
grind and repair of the cracked spraying tube of desuperheater at A side etc.
have been adopted.After implementation
the steam temperature at A side can be controlled within 540 ℃
the problem of over-temperature at outlet of platen superheater has been efficienly controlled.