CHEN Hua-gui1, TIAN Li21.Jiangsu Provincial Electric Power Testing and Research Institute Co Ltd. ANALYSIS AND DISPOSAL OF VIBRATION ON ULTRA-SUPERCRITICAL TURBO-GENERATOR SET[J]. Thermal power generation, 2009, 38(6): 61-64.
CHEN Hua-gui1, TIAN Li21.Jiangsu Provincial Electric Power Testing and Research Institute Co Ltd. ANALYSIS AND DISPOSAL OF VIBRATION ON ULTRA-SUPERCRITICAL TURBO-GENERATOR SET[J]. Thermal power generation, 2009, 38(6): 61-64.DOI:
Directing against the abnormal vibration problem occurred during the time of start-up debugging of unit no.1 in Kanshan Power Plant
Jiangsu Province
through vibration monitoring
the collected vibration data and diagrams have been studied and analysed
finding out that the shaft vibration at bearings no.5 and no.6 of the generator was far in excess of the set standard mainly due to smaller gap on the outer oil retainer and impact-rubbing between movable and stationary parts in the generator.On basis of these
corresponding measures have been proposed
the tips of comb-teeth on the outer oil retainer being thinned out.After implementation
the problem of abnormal vibration of unit has been successfully solved