SUN Zhi-hong, FAN Ai-bingHuadian Yangzhou Power Generation Co Ltd. MEASURES FOR ENHANCING VACUUM IN OPERATION OF CONDENSER[J]. Thermal power generation, 2009, 38(8): 93-95.
SUN Zhi-hong, FAN Ai-bingHuadian Yangzhou Power Generation Co Ltd. MEASURES FOR ENHANCING VACUUM IN OPERATION OF CONDENSER[J]. Thermal power generation, 2009, 38(8): 93-95.DOI:
The vacuum value in condenser is closely related to safety and economic efficiency of the steam turbine unit
through cause analysis of low vacuum in operation of unit no.7 in Yangzhou Power Generation Co Ltd
it is believed that the main factors affecting low vacuum in operation of said unit are as follows:smaller total heat exchange coefficient of the condenser;lower flow rate of the cooling water;and abnormal operation of the air-extracting system
etc..For these
effective ways and solving measures for enhancing the vacuum
such as retrofitting the circulating water pump
and descaling from tubes in condenser
etc.have been put forward.Through implementation of the retrofit scheme
the vacuum in operation of said condenser has been enhanced by 4 kPa.