XI Guang-hui, ZHANG JunDatang Xutang Power Generation Co Ltd. RETROFITTING AIR PREHEATER OF BOILER TO ADOPT CONTACTING TYPE FLEXIBLE SEAL[J]. Thermal power generation, 2009, 38(8): 73-75.
XI Guang-hui, ZHANG JunDatang Xutang Power Generation Co Ltd. RETROFITTING AIR PREHEATER OF BOILER TO ADOPT CONTACTING TYPE FLEXIBLE SEAL[J]. Thermal power generation, 2009, 38(8): 73-75.DOI:
锅炉空气预热器柔性接触式密封改造
摘要
对大唐徐塘发电有限责任公司300 MW机组锅炉回转式空气预热器存在漏风率偏大的问题进行了分析
认为漏风偏大主要由运行中转子径向膨胀大于冷端膨胀
以及转子中心轴向上膨胀
使转子产生蘑菇状变形
扇形板与转子端面密封间隙变大引起。对回转式空气预热器进行了柔性接触式密封技术改造
改造后漏风率由12%下降为5.5%
效果明显
达到了改造的预期目的。
Abstract
The problem of high air leakage rate existing on rotary air preheater of boielr for 300 MW unit in Xutang Power Generation Co Ltd has been analysed.It is believed that the main causes leading to high air leakage are as follows:the radial expansion of rotor in operation is larger than the cold end expansion;the axial expansion of rotor centre makes the rotor to produce mushroom-shaped deformation;the sealed gap between segment plate and the end-face of rotor being increased.The rotary air preheater has been retrofitted to adopt contacting type flexible seal.After retrofitting