国华太仓发电厂超临界机组直流锅炉给水加氧处理实践
摘要
对国华太仓发电有限公司(太仓发电厂)2×630MW超临界机组直流锅炉压差高且上升快的原因进行分析
确认原给水采用的全挥发处理工艺不适宜该机组。对此
通过试验调整
最终确定给水采用加氧处理
处理后水汽系统的含铁量大幅度降低
省煤器入口给水含铁量降至1.0μg/L以下
高压加热器疏水含铁量也小于1.0μg/L;与此同时
锅炉压差稳定在一相对较低的水平。实践表明
超临界机组直流锅炉给水宜采用加氧处理工艺。
Abstract
The causes leading to high pressure difference and its rapid rise in once-through boilers of 2×600 MW supercritical units in Guohua Taicang Power Generation Co Ltd have been analysed.It is believed that the total volatilization treatment technology originally adopted for the feed-water isn't suitable for said units.For this
through test and adjustment
it is finally determined to use the oxygen-adding treatment technology for the feed-water.After said treatment
the iron content in the water-steam system has been decreased by a big margin
the iron content in feed-water at inlet of the economizer has reduced to below 1.0 μg/L
and the iron content in drain from the high-pressrue heater is also less than 1.0 μg/L
at the same time
the pressure difference in boilers is stabilized at a relatively lower level.Practice shows that the oxygen-adding treatment technology is suitable for being adopted to once-through boilers of supercritical units.