XUE Shou-hong1, WEI Zhi-gang1, XU Pei1, et al. TEST AND ANALYSIS OF FREQUENT TUBE-BURST ON THE STEAM-COOLED WALL OF BOILER NO.1 IN ONE POWER PLANT[J]. Thermal power generation, 2010, 39(1): 105-108.
XUE Shou-hong1, WEI Zhi-gang1, XU Pei1, et al. TEST AND ANALYSIS OF FREQUENT TUBE-BURST ON THE STEAM-COOLED WALL OF BOILER NO.1 IN ONE POWER PLANT[J]. Thermal power generation, 2010, 39(1): 105-108.DOI:
某电厂1号炉包墙过热器频繁爆管试验分析
摘要
某电厂1号锅炉包墙过热器运行10年来共发生爆管、泄漏30余次
利用化学成分分析、金相组织分析
以及扫描电镜、俄歇能谱等方法对其进行了分析。结果表明
包墙管材质12Cr1MoV中有害元素(As、Sn)含量过高使该管材产生回火脆性
加之焊接工艺不当促进了这种脆性程度
是造成频繁爆管的主要原因。为此
建议对包墙过热器管材进行更换。
Abstract
Tube-burst and leakage on the steam-cooled wall of boiler no.1 in one power plant had occurred more than thirty times in ten years of operation.By using chemical analysis
metallurgical structure analysis
as well as scanning electron microscope
and auger spectrometer etc.
the tube-burst and leakage have been analysed.Resrlts show that the harmful elements content of As + Sn being too high in pipe material of said steam-cooled wall made the pipe material to produce temper brittleness
and unsuitable weld procedure made the said brittleness to be more serious
were the main causes leading to tube-burst and leakage.For this
it is recommended that the pipe material of said steam-cooled wall has to be replaced.