HUANG Yi-huiRed Bay Power Generation Co Ltd. CAUSE ANALYSIS OF IMPELLER FRACTURE FOR SLURRY-RECIRCULATING PUMPS IN SHANWEI POWER PLANT[J]. Thermal power generation, 2010, 39(2): 65-68.
HUANG Yi-huiRed Bay Power Generation Co Ltd. CAUSE ANALYSIS OF IMPELLER FRACTURE FOR SLURRY-RECIRCULATING PUMPS IN SHANWEI POWER PLANT[J]. Thermal power generation, 2010, 39(2): 65-68.DOI:
Severe fracture of impeller had successively occurred in slurry-recirculating pumps equipped for the Absorption tower of lime-stone/gypsum wet flue gas desulphurization(FGD) system for boilers of 600 MW units NO.1 and NO.2 in Shanwei Power Plant.Through metallographic examination
chemical composition analysis
and hardness test etc.
it is believed that the cause leading to base corrosion of impeller blades is the low pH value of slurry from the Absorption tower
reducing the strength of impeller.In addition
the abrasion of slurry further accelerates the fracture of impeller.For this
it is recommented to control the pH value of slurry from the Absorption tower
eliminating cavitation phenomenon in the pumps
selecting materials with high strength
high toughness
and strong corrosion-resisting property for manufacturing the impeller
as well as the rotational speed of pumps should be designed within 450~530 r/min.