STUDY ON AND COUNTERMEASURES FOR ERRORS APPEARED IN MEASUREMENT OF DIFFERENTIAL EXPANSION IN LOW-PRESSRUE CYLINDER FOR 600 MW STEAM TURBINE MANUFACTURED BY ALSTOM
RONG Zhao-yang, HAN Ji-wen Guodian Beilun Power Plant. STUDY ON AND COUNTERMEASURES FOR ERRORS APPEARED IN MEASUREMENT OF DIFFERENTIAL EXPANSION IN LOW-PRESSRUE CYLINDER FOR 600 MW STEAM TURBINE MANUFACTURED BY ALSTOM[J]. Thermal power generation, 2009, 38(12): 78-81.
RONG Zhao-yang, HAN Ji-wen Guodian Beilun Power Plant. STUDY ON AND COUNTERMEASURES FOR ERRORS APPEARED IN MEASUREMENT OF DIFFERENTIAL EXPANSION IN LOW-PRESSRUE CYLINDER FOR 600 MW STEAM TURBINE MANUFACTURED BY ALSTOM[J]. Thermal power generation, 2009, 38(12): 78-81.DOI:
Directing against the problem of differential expansion in low-pressrue cylinder of 600 MW steam burbine manufactured by ALSTOM is far larger in the winter season
and affecting safe and economic operation of the unit
the probe of differential expansion in low-pressure cylinder
the cooling of prebox
and the temperature characters of prebox have been tested.It is believed that the main causes leading to large error in measurement of differential expansion of low-pressure cylinder in winter season are the bad quality of prebox WL172A+AO--02-11C used for measuring differential expansion in low-pressure cylinder
and the remarkable influence of ambient temperature variation upon the output value of measurement.For this
the position of prebox has been removed
making the influence of ambient temperature in winter season to be substantially reduced