MA Ying, ZHOU Hongguang Beijing Guohua ELectric Power Co Ltd. STUDY ON OPERATION OF WET DESULPHURIZATION SYSTEM FOR FLUE DUCT WITHOUT BYPASS[J]. Thermal power generation, 2010, 39(8): 96-97.
MA Ying, ZHOU Hongguang Beijing Guohua ELectric Power Co Ltd. STUDY ON OPERATION OF WET DESULPHURIZATION SYSTEM FOR FLUE DUCT WITHOUT BYPASS[J]. Thermal power generation, 2010, 39(8): 96-97.DOI:
无旁路烟道的湿法脱硫系统运行研究
摘要
针对锅炉无旁路烟道脱硫装置的运行情况
研究了防止锅炉点火起动过程燃油和粉尘危害脱硫装置
提高脱硫系统的运行可靠性和安全性的问题
并提出了优化吸收塔内设备的设计和设置安全可靠的烟气事故喷淋装置等解决方案。
Abstract
Directing against the operation situation of boiler and desulphurization system for flue duct without bypass
the problems of preventing fuel oil and dust to harm the desulphurizaton system in the process of boiler ignition and start-up
and enhancing the reliability and safety in operation of the desulphurization system have been studied