SUN Xiaojun1, SANG Junzhen1, MA Shisong2, et al. APPLICATION OF OCTADECYLAMINE METHOD IN SHUTDOWN CONSERVATION OF NEWLY CONSTRUCTED SUPERCRITICAL UNITS[J]. Thermal power generation, 2010, 39(10): 100-103.
SUN Xiaojun1, SANG Junzhen1, MA Shisong2, et al. APPLICATION OF OCTADECYLAMINE METHOD IN SHUTDOWN CONSERVATION OF NEWLY CONSTRUCTED SUPERCRITICAL UNITS[J]. Thermal power generation, 2010, 39(10): 100-103.DOI:
Taking supercritical unit in Shenhua Hebei Guohua Huanghua Power Plant as an example
the protection range
dosing equipment
dosing conditions
matters needing to pay attention
dosing procedure
effects evaluation
as well as cold flushing and hot flushing during complete set start-up
and the reasonable time for condensate polishing treatment have been presented in detail for carrying out octadecylamine(ODA) shutdown conservation after steam blowout of the newly constructed units.Results of inspection after shutdown
as well as results of cold and hot flushing during the process of units start-up show that the formed protective film has remarkable hydrophobicity
and has long time in spot-out test using copper sulfate
the ODA content and iron content in process of cold and hot flushing are rapidly up to set standard
th ODA shutdown conservation method has excellent effectiveness in shutdown conservation.