HUANG Wanqi, CAO Songyan, CHANG Xuhong, et al. ANALYSIS OF PROBLEMS EXISTING IN THE SYSTEM CONNECTING CATION BED AND ANION BED IN SERIES FOR CONDENSATE POLISHING TREATMENT AND IMPROVEMENT THEREOF[J]. Thermal power generation, 2010, 39(8): 67-71.
HUANG Wanqi, CAO Songyan, CHANG Xuhong, et al. ANALYSIS OF PROBLEMS EXISTING IN THE SYSTEM CONNECTING CATION BED AND ANION BED IN SERIES FOR CONDENSATE POLISHING TREATMENT AND IMPROVEMENT THEREOF[J]. Thermal power generation, 2010, 39(8): 67-71.DOI:
A system connecting cation bed and anion bed in series for condensate polishing treatment was used for 2×300 MW direct air-cooled units in one power plant
the main problems existing in operation of said system are as follows:(1)in the initial period of putting cation bed and anion bed into operation
contaminant ion leakage had occurred in the effluent water;in case of cation bed is in operation according to ammonium type
chlorine ion leakage appeared in effluent water from the anion bed.For this
improvement scheme has been put forward after discuss and analysis in the following:(1)enhancing regenerative level of the resins;(2)sufficiently positive cleaning
after the end of flushing resin in the storage tank
the conductivity of effluent water should be less than 1 μS/cm;(3)designing reasonable cyclic flushing system for initial period of putting cation bed and anion bed into operation
and reasonably arrange the manipulation of putting them into operation.After implementation of the improvement scheme
the ion leakage problem existing in original system has been basically solved.