LI Shunhua, LI Pengyun Electric Power Science Research Institute under Guangdong Power Grid Gorporation. ANALYSIS OF LOCALIZED CORROSION ON SUPER304H STEEL TUBES USED FOR BOILERS AND PREVENTIVE COUNTERMEASURES THEREOF[J]. Thermal power generation, 2011, 40(1): 87-90.
LI Shunhua, LI Pengyun Electric Power Science Research Institute under Guangdong Power Grid Gorporation. ANALYSIS OF LOCALIZED CORROSION ON SUPER304H STEEL TUBES USED FOR BOILERS AND PREVENTIVE COUNTERMEASURES THEREOF[J]. Thermal power generation, 2011, 40(1): 87-90.DOI:
The localized corrosion occurred on SUPER304H steel tubes used for boilers of units under construction in coastal areas has been analysed by using macroscopic examination
chemical composition test
metallographic detection
scanning electron microscope
and energy spectrum.Results show that the main cause leading to localized corrosion on SUPER304H steel tubes is due to chlorine ions.For this
it is recommended that the said steel tubes should be covered with canvas during sea transportation and storage
and being protected with corroson inhibitors.The tube materials
which are already being corroded
should be rubbed
and examined through liquid penetration test and wall thickness measurement