Many times of servo valve's abnormal action have occurred in DEH control system of a 300 MW steam turbine in one power plant of Henan Province
made the regulating valve to be abnormally closed and to be automatically opened
resulting in large load fluctuation of the unit
seriously affecting safe and economic operation of the steam turbine.For this
through analysis in many aspects
it is believed that the oil-sludge resulted from contamination and deterioration of fire-resistant oil is the main cause leading to abnormal action of the servo valve.Using the opportunity of repair after shutdown
a fully cleaning and flushing of the oil system has been carried out
and the fire-resistant oil being filtered
making the indices of fire-resistant oil
such as the particle size
the acidic value
and the resistivity etc.
to be up the set standard
finally
making the frequency of load fluctuation for said unit being greatly reduced