GAO Deshun, GONG Jiahong Huaneng Dalian Power Plant. RETROFIT MEASURES OF THE ROTARY AIR PREHEATERS[J]. Thermal power generation, 2011, 40(3): 55-57.DOI:
回转式空气预热器的改进措施
摘要
针对回转式空气预热器(空预器)普遍存在的漏风大、冷端易腐蚀和堵灰等问题
采取了双密封技术、固定密封技术
以及利用固定式水洗装置进行在线水冲洗
检修时采用高压水射流清洗
空预器冷端受热面选用COR-TEN钢、搪瓷和陶瓷材料等耐腐蚀材料等措施
实施后上述问题得以解决。
Abstract
Directing against the problems existing commonly in rotary air preheaters
such as large air leakage
as well as corrosion and ash-clog occurred easily on the cold end etc.
analysis has been carried out
and retrofit measures being put forward
including adoptation of double-seal and fixed seal technologies
using fixed water flushing facility to realize on-line water flushing
and using high-presurre water to carried out jet cleaning during repair
and the cold end of air preheater has to use corrosion resistant materials
such as COR-TEN steel
enamel and ceramic materials etc..After implementation
the above-mentioned problems all have been resolved.