ZHANG Cuizhen1, YANG Mo1, LU Mei1, et al. COMPREHENSIVE EVALUATION OF RESIDUAL HEAT UTILIZATION FOR HEATING FURNACE BASED ON MIXED HIERARCHICAL ANALYSIS METHOD[J]. Thermal power generation, 2010, 39(11): 22-26.
ZHANG Cuizhen1, YANG Mo1, LU Mei1, et al. COMPREHENSIVE EVALUATION OF RESIDUAL HEAT UTILIZATION FOR HEATING FURNACE BASED ON MIXED HIERARCHICAL ANALYSIS METHOD[J]. Thermal power generation, 2010, 39(11): 22-26.DOI:
By using the mixed grey associated hierarchical analysis method
the comprehensive evaluation of four co-generation schemes for the residual heat utilization of high-temperature flue gas from the heating furnace of one steel rolling mill has been carried out.The weight of four indices
i.e.payback period of the investment
utilization ratio of the total energy
decrement of CO2
emission
and convenience in maintenance
has been calculated by using the hierarchical analysis theory
and the evaluation matrix being determined by using the mixed analysis method
the comprehensive judgement being completed through weighted summarization.The sequence of optimized selection for residual heat utilization scheme of high-temperature flue gas from heating furnace of said steel rolling mill is as follows:heat and electricity co-generation
cool
heat
and electricity co-generation;cool and heat cogeneration;electricity generation using waste heat.The said evaluation method can also be used for other evaluation systems with multi-attribute.