对华能巢湖电厂一期2×600 MW机组原保安电源控制系统存在的接线、二次回路、同期检查回路以及控制逻辑复杂
使得控制可靠性差进行了改进
将保安电源系统由PLC控制改为DCS控制
并在调试过程中对保安电源控制系统出现的DCS与柴油发电机的接口、负荷投切、保安段失电判据等问题进行了完善。改造后的保安电源控制系统具有硬件功能完整、响应速度快、可靠性高、维护方便等特点。
Owing to worse reliability of original safety power source control system of 2×600 units in first-phase project of Huaneng Caohu Power Plant
resulting from complexity in wire connection
secondary circuit
synchronism-inspecting circuit
and control logics
improvement has been carried out
the safety power source system being retrofitted from PLC control to DCS control
and the problems occurred in safety power source control system
such as interface between DCS and diesel-generator
switchover of load
criterion for power loss in safety section etc.
being perfected.After retrofitting
the safety power source control system boasts advantages of full hardware functions
rapid response speed
high reliability
and convenience in maintenance.