CHENG Zhihong Guangdong Zhuhai Jinwan Power Generation Co Ltd. CAUSE ANALYSIS OF TUBE-BURST IN FINAL-STAGE SUPERHEATER OF BOILER EQUIPPED FOR SUPERCRITICAL 600 MW UNIT AND PREVENTIVE MEASURES THEREOF[J]. Thermal power generation, 2011, 40(7): 81-83.
CHENG Zhihong Guangdong Zhuhai Jinwan Power Generation Co Ltd. CAUSE ANALYSIS OF TUBE-BURST IN FINAL-STAGE SUPERHEATER OF BOILER EQUIPPED FOR SUPERCRITICAL 600 MW UNIT AND PREVENTIVE MEASURES THEREOF[J]. Thermal power generation, 2011, 40(7): 81-83.DOI:
The situation of tube-burst due to oxide skin fall-off leading to blockage in final-stage superheater of Jinwan Power Generation Co Ltd has been presented.From aspects of maintenance and operation etc.for the boiler
preventive measures for controlling oxide skin formation and fall-off in the superheater
such as replacing tubes
controlling steam temperature
reducing heat deviation in combustion
controllng temperature rising speed
controlling temperature reducing speed