ZHANG Xueyan Xi'an Thermal Power Research Institute Co Ltd. INFLUENCE OF THE SHAFT VOLTAGE(CURRENT) ON TURBO-GENERATOR SET UPON SHAFT VIBRATION THEREOF[J]. Thermal power generation, 2011, 40(12): 64-66.
ZHANG Xueyan Xi'an Thermal Power Research Institute Co Ltd. INFLUENCE OF THE SHAFT VOLTAGE(CURRENT) ON TURBO-GENERATOR SET UPON SHAFT VIBRATION THEREOF[J]. Thermal power generation, 2011, 40(12): 64-66.DOI:
汽轮发电机组轴电压(流)对轴系振动的影响
摘要
结合汽轮发电机组现场振动故障的诊断及处理实例
对机组轴电压(流)产生的原因、危害及其对轴系振动的影响进行了总结。分析认为
机组轴电压(流)产生的主要原因为绝缘不良、碳刷接触不良
其对机组轴系振动的影响主要是引起轴系或轴承振动特性恶化
出现虚假的振动信号
引起振动保护动作。
Abstract
Combined with actual examples concerning vibration falt diagnosis and disposal for four turbo-generator sets
the causes leading to occurrence of shaft voltage(current) as well as its harm and influence upon shaft vibration have been summarized and analysed.It is believed that the main causes resulting in occurrence of shaft voltage on the turbo-generator set are bad insulation and bad contact of carbon brushes.The influence of shaft voltage is mainly resulting in deterioration of shaft or bearing vibration characteristics