DIAGNOSIS AND ANALYSIS OF ENERGY-SAVING IN TYPICAL THERMODYNAMIC SYSTEM
热力发电2011年40卷第7期 页码:58-61
作者机构:
1. 国电科学技术研究院
2. 国电环境保护研究院
作者简介:
基金信息:
DOI:
中图分类号:TM621.4
纸质出版:2011
稿件说明:
移动端阅览
邵峰, 周胜男. 典型热力系统节能诊断分析[J]. 热力发电, 2011,40(7):58-61.
SHAO Feng1, ZHOU Shengnan2 1.Guodian Science and Technology Research Institute. DIAGNOSIS AND ANALYSIS OF ENERGY-SAVING IN TYPICAL THERMODYNAMIC SYSTEM[J]. Thermal power generation, 2011, 40(7): 58-61.
SHAO Feng1, ZHOU Shengnan2 1.Guodian Science and Technology Research Institute. DIAGNOSIS AND ANALYSIS OF ENERGY-SAVING IN TYPICAL THERMODYNAMIC SYSTEM[J]. Thermal power generation, 2011, 40(7): 58-61.DOI:
A simple and convenient diagnosis method of energy-saving has been put forward
and the analysis and calculation being carried out by using the performance test data and the turbine's structural data.The operation performance diagnosis of flow passage in steam turbine
as well as of heat regeneration system
feed-water pump
small steam turbine
desuperheating water
shaft seal system
condenser
pressure loss of the extracted steam
loss of steam and water
and all parameters in operation has been carried out for a typical 330 MW unit
and the energy loss distribution diagram being given.The diagnosis shows that the total deviation of heat consumption for all factors is 448.25 kJ/kWh
tallying well with the designed value and tested value.