MA Chong, CHEN Shaoyu Technological Center under Tianjin City Electric Power Company. CAUSE ANALYSIS OF TUBE-BURST ON PLATEN SUPERHEATER OF BOILER EQUIPPED FOR ULTRA-SUPERCRITICAL 1000 MW UNIT[J]. Thermal power generation, 2011, 40(11): 91-94.
MA Chong, CHEN Shaoyu Technological Center under Tianjin City Electric Power Company. CAUSE ANALYSIS OF TUBE-BURST ON PLATEN SUPERHEATER OF BOILER EQUIPPED FOR ULTRA-SUPERCRITICAL 1000 MW UNIT[J]. Thermal power generation, 2011, 40(11): 91-94.DOI:
超超临界1000MW机组锅炉屏式过热器爆管原因分析
摘要
某电厂超超临界1 000MW机组锅炉屏式过热器同一根管连续发生2次爆管事故
经对爆管宏观检查
化学成分分析
拉伸、金相、扫描电镜和能谱分析等
表明爆管的主要原因是管内有异物堵塞
造成管子通流面积减少使蒸汽对管子的冷却作用降低
局部处于超温状态
高温蠕变强度降低所致。
Abstract
On a same pipe of the platen superheater in boiler of ultra-supercritical 1 000 MW unit in one power plant
two times of tube-burst have successively occurred.Through macroscopic inspection
chemical composition analysis
tensile test
metallographic examination
scanning electronic microscopic and energy spectrum analysis etc.
it shows that the main cause leading to tube-burst is the blockage of foreign maters in the said tube
resulting in reduction of flow passage area in the tube
making the cooling effect of steam onto the tubes to be reduced
and a part of them was in an overtemperature condition
thereby
the high-temperature creep strength being reduced.