MAO Xiaofei1, WEI Youling2, SHI Quancheng3, et al. STUDY ON FLUE GAS TEMPERATURE REGULATION CHARACTERS AT FURNACE OUTLET OF 670t/h CFB BOILER[J]. Thermal power generation, 2011, 40(12): 49-53.
MAO Xiaofei1, WEI Youling2, SHI Quancheng3, et al. STUDY ON FLUE GAS TEMPERATURE REGULATION CHARACTERS AT FURNACE OUTLET OF 670t/h CFB BOILER[J]. Thermal power generation, 2011, 40(12): 49-53.DOI:
Under thirty operating conditions of one HG 670/13.7-LPM19 type CFB boiler
the measurement has been carried out.By using optimal regression analysis method
some factors affecting the flue gas temperature variation at furnace outlet
such as boiler load
ash in fuel coal on received basis(RB)
volatile matters on RB
net calorific value on RB
particle size of feed coal
bed pressure
primary air flow rate
upper secondary air flow rate
lower secondary air flow rate
oxygen quantity at the furnace outlet etc.
have been analysed.The magnitude of influence resulted from the said parameters' variation
from big to small
is listed as in the following:air distribution mode
bed pressure
oxygen quantity
particle size of feed coal.The change of bed pressure and particle size of feed coal requires longer time
being not used to regulate the flue gas temperature at furnace outlet under general conditions.In order to prevent over-temperature of flue gas at furnace outlet
under prerequisity of keeping other parameters to be stable
the most convenient
rapid
and effective meams is changing the air distribution mode or enhancing the oxygen quantity.The influence of related parameters is different in tendency and magnitude.