ZHANG Xiangtao, ZHANG Xiaogang, LI Jianxi, et al. CAUSES LEADING TO CORROSION IN CO2-CAPTURING SYSTEM OF FLUE GAS FROM COAL-FIRED BOILERS AND SCREENING TEST OF INHIBITORS[J]. Thermal power generation, 2012, 41(2): 81-83.
ZHANG Xiangtao, ZHANG Xiaogang, LI Jianxi, et al. CAUSES LEADING TO CORROSION IN CO2-CAPTURING SYSTEM OF FLUE GAS FROM COAL-FIRED BOILERS AND SCREENING TEST OF INHIBITORS[J]. Thermal power generation, 2012, 41(2): 81-83.DOI:
The causes leading to corrosion in CO2-capturing system of flue gas from boilers in one power plant have been analysed
and a test for developing inhibitors aimed directly at the said corrosion being carried out.Taking TP304 and 16MnR as objects
several single inhibitors with better performance have been selected by using static hanging pieces to carry out recombination of said single inhibitors.After further screening the recombined inhibitors
the environment in decomposition tower of the CO2-capturing system has been simulated in one high-temperature reaction cauldron
the selected inhibitors in test for 16MnR and TP304
the corrosion rate of them is 0.067 6 mm/a and 0.002 8 mm/a respectively