PAN Guomin, ZHENG Yu, CHEN Naijuan Shanghai Electric Power Equipment Repair and Manufacture Works Co Ltd. NUMERICAL CALCULATION OF THREE-DIMENSIONAL FLOW FIELD IN FEED-WATER PUMP OF BOILER EQUIPPED WITH ULTRA-SUPERCRITICAL UNITS[J]. Thermal power generation, 2012, 41(3): 68-70.
PAN Guomin, ZHENG Yu, CHEN Naijuan Shanghai Electric Power Equipment Repair and Manufacture Works Co Ltd. NUMERICAL CALCULATION OF THREE-DIMENSIONAL FLOW FIELD IN FEED-WATER PUMP OF BOILER EQUIPPED WITH ULTRA-SUPERCRITICAL UNITS[J]. Thermal power generation, 2012, 41(3): 68-70.DOI:
and adopting the standard k-ε turbulence model and the upgradable wall-surface function metod
a three-dimensional steady turbulent flow field in the feed-water pump of boiler equipped with 1 000 MW unit has been calculated
the velocity and pressure distribution of flow field within the main parts
namely impeller and guide vanes
being achieved.Analysis of numerical calculation results and the predicted characteristic curves of the feed-water pump show that the relative error between the predicted discharge head of said feed-water pump and the tested value is in a range of 1.8%~7.8%
and the relative error between the predicted efficiency of feed-water pump and the tested value is in a range of 3.85%~6.3%