ZHANG Lunzhu1, WANG Yunmin1, XU Damao2, et al. STUDY ON ANALYSIS AND APPLICATION OF CHARACTERISTIC FLOW PASSAGE AREA IN STEAM TURBINES[J]. Thermal power generation, 2012, 41(3): 29-31.
ZHANG Lunzhu1, WANG Yunmin1, XU Damao2, et al. STUDY ON ANALYSIS AND APPLICATION OF CHARACTERISTIC FLOW PASSAGE AREA IN STEAM TURBINES[J]. Thermal power generation, 2012, 41(3): 29-31.DOI:
an expression formula of the characteristic flow passage area in steam turbines has been given through mathematic deduction.Combined with one ultra-supercritical 600 MW unit
results of calculation show that the variation of deviation value concerning the characteristic flow passage area of every stage-group(not including stage-group no.7) is within ±1.5% when the unit is in operation under variable condition with 50%~100% rated load.Besides
the ways regarding application of characteristic flow pasage area in many aspects
such as the performance analysis in operation of unit
the establishment of thermal performance database of single unit
the calculation of variable operation condition
as well as the on-line monitoring and diagnosis etc.