LI Haiguang, ZHAO Zengwu, LI Ke, et al. TEST STUDY ON WORKING BEHAVIOR OF J-TYPE VALVE USED FOR CFB BOILER[J]. Thermal power generation, 2012, 41(4): 36-39.
LI Haiguang, ZHAO Zengwu, LI Ke, et al. TEST STUDY ON WORKING BEHAVIOR OF J-TYPE VALVE USED FOR CFB BOILER[J]. Thermal power generation, 2012, 41(4): 36-39.DOI:
The J-type valve is a kind of facility used frequently to return materials into risers in CFB boilers
its working behavior is very important for ensuring normal operation of the CFB boiler.A method for analysing and evaluating the working behavior of J-type valve based on pressure difference on key parts in the CFB boiler
such as the pressure difference of material layer in the riser
the pressure difference between air quantity in returned material and the main air compartment
and the pressure difference of material layer in the furnace etc.
has been put forward
and the said method being tested on the cold-state test stand.Results of test show that the measurement of pressure difference variation on key location in the furnace is helpful to undestand the working behavier of the J-type valve
providing method and measure for solving the problems