LI Bin1, 2, LI Jianfeng2, et al. EXERGY ANALYSIS FOR EFFICIENCY ENHANCEMENT OF THE 135 MW UNIT WITH CFB BOILER[J]. Thermal power generation, 2012, 41(10): 13-17.
LI Bin1, 2, LI Jianfeng2, et al. EXERGY ANALYSIS FOR EFFICIENCY ENHANCEMENT OF THE 135 MW UNIT WITH CFB BOILER[J]. Thermal power generation, 2012, 41(10): 13-17.DOI:
The exergy efficiency and loss of each link in power generation was revealed by exergy analysis for efficiency of a 135 MW unit with circulating fluidized bed(CFB) boiler.Results show that
for the135 MW unit that working with the CFB boiler
the exergy loss during combustion and heat transfer process are the two maximum parts of all exergy losses.Meanwhile
to improve the performance of the unit system
methods for decreasing such indexes as the exergy loss during combustion and heat transfer
the condenser backpressure and carbon content in fly ash etc.are discussed.