FU Zhiming, DENG Yunyao, ZHANG Hongyan, et al. CALCULATION METHOD OF REDUCTANT CONSUMPTION IN SCR FLUE GAS DENITRIFICATION FOR COAL-FIRED POWER PLANT[J]. Thermal power generation, 2012, 41(4): 40-41.
FU Zhiming, DENG Yunyao, ZHANG Hongyan, et al. CALCULATION METHOD OF REDUCTANT CONSUMPTION IN SCR FLUE GAS DENITRIFICATION FOR COAL-FIRED POWER PLANT[J]. Thermal power generation, 2012, 41(4): 40-41.DOI:
The ammonia is commonly used as reductant in SCR denitrification system
which can be prepared from materials
such as liquid ammonia
ammonia water
ammonium bicarbonate
and urea etc..The calculation method of consumption for using above-mentioned materials respectively as reductant in SCR denitrification and their safety in utilization have been presented.When using liquid ammonia and ammonia water as reductant
the cost in storage
transportation
and preparation is lower
but certain danger exsists;the safety of urea is better
but the cost is higher;and its decomposition is difficult;the ammonium bicarbonate can be prepared by using two methods