ZHANG Xiaotao1, JIN Fei1, GE Yan2 1.Institute of Electric Power. FEED WATER FLOW MEASUREMENT DEVIATION IN ONCE-THROUGH BOILER:REASON ANALYSIS AND SOLUTIONS[J]. Thermal power generation, 2012, 41(10): 58-60.
ZHANG Xiaotao1, JIN Fei1, GE Yan2 1.Institute of Electric Power. FEED WATER FLOW MEASUREMENT DEVIATION IN ONCE-THROUGH BOILER:REASON ANALYSIS AND SOLUTIONS[J]. Thermal power generation, 2012, 41(10): 58-60.DOI:
Based on analysis of feed water flow measurement deviation in once-through boiler
measurements were taken as follows:adopting independent sampling of feed water flow;using positive pressure side second valve
negative pressure side second valve and balance valve that composed of needle type valve set which can bear pressure more than 40 MPa to replace three valve groups
and to connect to junction of positive pressure side and negative pressure side by screw adding gasket;increasing heat tapes of pipeline.Meanwhile
to measure the feed water flow accurately
it should be ensured that
the sampling devices are arranged reasonably
the sampling pipeline has no leakage
and measurement range of the transmitter is consistent with that of the I/O channel in DCS
furthermore
the DCS data transmission channel is normal.After the treatment
feed water flow deviation values measured at three points were less than 50t/h.