CHEN Junjun, PANG Yunji, CHEN Yisheng, et al. TOWER TYPE CHIMNEY HEIGHT AND AUXILIARY HEATING FOR SOLAR CHIMNEY POWER GENERATION SYSTEM[J]. Thermal power generation, 2012, 41(12): 68-69.
CHEN Junjun, PANG Yunji, CHEN Yisheng, et al. TOWER TYPE CHIMNEY HEIGHT AND AUXILIARY HEATING FOR SOLAR CHIMNEY POWER GENERATION SYSTEM[J]. Thermal power generation, 2012, 41(12): 68-69.DOI:
太阳能热气流发电系统辅助加热与塔囱高度研究
摘要
对太阳能塔囱热气流发电系统中辅助加热与塔囱高度的关系进行了分析研究
提出了在塔囱内对上升热气流进行二次辅助加热的设想
以增加气流速度
提高塔囱抽力
降低塔囱高度。以乌海沙漠太阳能热风气流发电系统为例
在塔囱压差和底部入口气流速度不变的情况下
最佳辅助加热气流温度为90℃;塔囱高度为80m时
辅助加热位置设在塔囱内距地面50m处较为合适。
Abstract
This paper investigated the relationship between the auxiliary heating and the tower type chimney height in solar chimney power system.Aimed at lowering the chimney height so as to reduce the construction cost
assumption that reheating the ascending hot gas flow inside the stack to enhance the internal energy of gas
raise the flow speed and increase the chimney draft was proposed.Taking the Wuhai desert solar chimney power system as the research object
under the condition of constant chimney differential pressure and bottom entrance flow rate
the optimal auxiliary heating flow temperature is 90 ℃
and the optimal tower type stack height is of 80 m
the reheating position should be inside the stack and of 50 m high from the ground.