QI Xiaojuan, LI Fengrui, LI Jian, et al. Numerical simulation of NOx emission from a 300 MW tangentially fired boiler[J]. Thermal power generation, 2013, 42(2): 49-53.
QI Xiaojuan, LI Fengrui, LI Jian, et al. Numerical simulation of NOx emission from a 300 MW tangentially fired boiler[J]. Thermal power generation, 2013, 42(2): 49-53.DOI:
The computational Fluid Dynamics(CFD) Fluent software was employed to simulate the combustion process numerically in a 300MW tangentially fired boiler.The distribution of the temperature field
velocity field and gas phase component concentration field in furnace were analyzed.Moreover
the NOx concentration distribution was obtained by post processing.The results showed that
the simulated combustion situation in furnace basically agreed with the actual operation of the tangentially fired pulverized coal boiler.The NO emission and reduction reaction mainly concentrated in the burner high temperature region.In burnout area
the NO concentration increased continuously
and the highest average NO concentration in horizontal-cross section appeared at the upper part of the overfire air burner where 30 meters high from the furnace bottom.The deviations of furnace outlet temperature and NOx emission between the simulation results and experimental data were all within 15%.