ZHOU Na1, LUO Lijia2, DAI Zhonghua3, et al. Effects of backwash gas pressure on ultra-filter operation with different water sources[J]. Thermal power generation, 2013, 42(3): 100-102.
ZHOU Na1, LUO Lijia2, DAI Zhonghua3, et al. Effects of backwash gas pressure on ultra-filter operation with different water sources[J]. Thermal power generation, 2013, 42(3): 100-102.DOI:
反洗气源压力对不同水源条件下超滤装置运行的影响
摘要
北方某电厂锅炉补给水水源由地下水更换为黄河下游水后
超滤装置透膜压差快速增加
平均净透水系数显著下降。分析表明其原因为超滤反洗气压不稳定所致。通过调整反洗气压在0.2MPa后
超滤装置透膜压差降低至0.032MPa
净透水系数恢复到1 300LMH/MPa左右。同时
建议每套超滤装置配备独立的减压阀和安全阀
以增加反洗过程的稳定性和安全性。
Abstract
After replacing underground water for Yellow River water as water source of boiler feedwater for a power plant located in the north of China
the trans-membrane pressure of ultra-filter device increased from 0.025 MPa to 0.05 MPa and the net average permeability coefficient dropped from above 1 870 LMH/MPa to 937 LMH/MPa after 6 hours' unit operation.According to the analysis
the instable backwash gas pressure was one of the important factors causing sharp drop of the net average permeability coefficient of ultra-filter
which had far more influence on unit employing Yellow River than that employing underground water.By adjusting and stabilizing the backwash gas pressure at 0.05 MPa
the trans-membrane pressure of ultra-filter device decreased to 0.032 MPa
and the net average permeability coefficient recovered to about 1 300 LMH/MPa.Moreover
to increase the stability and security of backwashing process
it suggested that independent pressure reducing valve(which has accurate adjustment and good pressure reducing performance at low pressure) and safety valve should be set on each ultra-filter device.