KONG Xiangqiang, MA Dianqun, LI Ying College of Mechanical and Electronic Engineering. Energy saving analysis on waste heat recovery of circulating cooling water for heating[J]. Thermal power generation, 2013, 42(6): 9-12.
KONG Xiangqiang, MA Dianqun, LI Ying College of Mechanical and Electronic Engineering. Energy saving analysis on waste heat recovery of circulating cooling water for heating[J]. Thermal power generation, 2013, 42(6): 9-12.DOI:
循环冷却水余热回收供热节能分析
摘要
分别采用低温循环冷却水和水源热泵供热技术
对某660MW机组热力系统排汽凝结热回收利用
消除凝汽器冷源损失。分析表明:原热力系统的主要热损失发生在凝汽器
占燃料输入热量的47.1%
机组燃料利用系数仅为40.1%
回收利用循环冷却水余热可以大幅度提高电厂能源利用率;采用低温循环冷却水供热技术
机组燃料利用系数为87.2%
发电功率减少了31MW
系统火用效率为53.9%;采用水源热泵供热技术
电厂燃料利用系数为87.1%
发电功率增加了23MW
系统火用效率为42.6%。
Abstract
With heat balance method
energy analysis was performed for the thermal system of a 660 MW unit
which showed that the main heat loss of the thermal system lied in the condenser
accounting for 47.1% of the heat input of the fuel
and the fuel utilization efficiency was only 40.1%.So the recovery and utilization of waste heat of circulating cooling water can greatly improve the energy efficiency of the power plant.The low-temperature circulating cooling water technology and water source heat pump heating technology were adopted to recover the exhaust steam condensation heat and eliminate the condenser cold source loss.On this basis
the heat balance and exergy balance method were applied to analyze the energy utilization.The result indicated that the unit fuel utilization efficient was 87.2%
the power generation decreased by 31 MW
and the system exergy efficiency was 53.9% when the low-temperature circulating cooling water heating technology was adopted.The fuel utilization efficient was 87.1%
the power generation increased by 23 MW
and the system exergy efficiency was 42.6% when the water source heat pump heating technology was applied.