YAN Naiming, LI Shanshan, GAO Zhigang HAEPC Electric Power Research Institute. Wet-dry state automatic switch control for once-through boilers[J]. Thermal power generation, 2013, 42(7): 79-82.
YAN Naiming, LI Shanshan, GAO Zhigang HAEPC Electric Power Research Institute. Wet-dry state automatic switch control for once-through boilers[J]. Thermal power generation, 2013, 42(7): 79-82.DOI:
直流炉干湿态自动转换控制研究
摘要
在直流炉湿/干态切换过程中
起动热力系统的运行状况非常复杂
手动控制易对系统产生较大扰动
特别是水煤比控制不当将导致干湿态之间频繁切换和机组参数的剧烈波动
从而影响机组正常运行。分析直流炉干湿态转换过程
提出了一种通过控制燃料量和给水流量实现干湿态自动转换的控制方案
并应用于某2×600MW机组直流炉。该方案实现了直流炉干湿态转换过程的全程自动控制。
Abstract
During the wet-dry state switch process of once-through boilers
operation condition of start-up thermal system is extremely complicated.Manual control can easily impose a disturbance on the system
especially inappropriate control of water-coal ratio can cause frequent wet-dry state switch and severe fluctuation of unit parameters
affecting the unit's normal operation.Through analysis on wet-dry state switch process of once-through boilers
an automatic wet-dry state switch scheme realized by controlling the fuel amount and feedwater quantity was proposed and applied in 2×600MW units once-through boilers of a power plant
helping this plant realizing full automation control of the dry-wet state switch.