LIN Bangchun, YU Yang Fujian Huadian Kemen Power Company Limited. Rotating blades regulating mechanism in axial fans : common failure diagnosis[J]. Thermal power generation, 2013, 42(8): 144-145.
LIN Bangchun, YU Yang Fujian Huadian Kemen Power Company Limited. Rotating blades regulating mechanism in axial fans : common failure diagnosis[J]. Thermal power generation, 2013, 42(8): 144-145.DOI:
轴流风机动叶调节机构常见故障诊断
摘要
以福建华电可门发电有限公司超临界4×600MW机组锅炉风机为例
介绍了动叶可调轴流风机动叶调节机构的构造和工作原理
以及国产调节机构液压系统与进口液压系统的区别
总结了该类型风机调节机构故障的原因及处理方法。分析得出
沈阳鼓风机厂制造的动叶可调轴流风机执行机构工作时
出现动叶动作缓慢
滞后于执行机构
且调节过程中调节臂脱落
是由于溢流阀失效、液压缸泄漏、调节油压设置过低
导致油压较低
调节力矩不够所致。
Abstract
The structure and working principle of rotating blades regulating mechanism for axial fans with adjustable blades were presented
and the difference between hydraulic system in domestic regulation mechanism and that in imported regulation mechanism was pointed out
taking boiler fans in supercritical 4×600MW units of Fujian Huadian Kemen Power Plant as the example.The main problem was that
during the operation of actuator in axial fans with adjustable blades manufactured by Shenyang Blower Factory
the rotating blades moved slowly and lagged behind the actuator
and the regulating arm will drop off.The relief valve failure
hydraulic cylinder leakage
low oil pressure resulted from low set value of regulating oil pressure
as well as the insufficient regulating torque were considered as the main reasons.Common regulating failures and their causes for this type of fans were summarized
and the determination methods for each fault were put forward.