LIU Honggang, ZHANG Guangcai, WANG Zhigang, et al. High temperature corrosion in wall-firing boiler:reason analysis and treatment[J]. Thermal power generation, 2013, 42(12): 129-131.
LIU Honggang, ZHANG Guangcai, WANG Zhigang, et al. High temperature corrosion in wall-firing boiler:reason analysis and treatment[J]. Thermal power generation, 2013, 42(12): 129-131.DOI:
墙式对冲燃烧锅炉高温腐蚀原因分析与治理
摘要
某机组锅炉水冷壁存在高温腐蚀问题
通过试验研究与分析认为
其主要因煤粉刷墙、两侧墙附近呈强还原性气氛以及存在高浓度H2S所致。对此
通过设备改造和专项治理后
两侧墙壁面气氛良好
高温腐蚀发生的条件消除
屏式过热器与高温再热器受热面不再超温
排烟中CO浓度在100μL/L以下
设备改造前后相同试验条件下SCR入口NOx变化在20mg/m3以内。
Abstract
High temperature corrosion occurred on two sides of water wall in a boiler.Experiment showes the pulverized coal scour on water wall tube
strong reductive atmosphere near side walls and high density of H2 S are the major reasons.Thus
regulations on relative equipments were conducted.After the improvement
the atmosphere at two sides of the water wall turned well
meaning the condition that may lead to high temperature corrosion was eliminated.The temperature at platen superheater and high temperature reheater surface was no longer over high.The CO concentration in flue gas dropped below 100μL/L
and the variation of NOx concentration at inlet of the SCR was within 20mg/m3 under the same experimental conditions before and after the equipment modification.