GU Qinghua. Application of regenerated catalyst in flue gas denitrification in a supercritical unit[J]. Thermal power generation, 2014, 43(5): 142-145.
GU Qinghua. Application of regenerated catalyst in flue gas denitrification in a supercritical unit[J]. Thermal power generation, 2014, 43(5): 142-145.DOI:
Experiments about application of regenerated catalyst in flue gas denitrification in a supercritical coal-fired unit was presented
including the pilot scale test
monolayer catalyst change and over-all unit catalyst change.The results show that
after the catalyst at the first layer in the SCR reactor was changed for the regenerated module
the differential pressure of catalyst at each layer decreased below the alarming value
and the NOxconcentration at outlet of the SCR reactor reduced to 74mg/m3
which satisfying the national standard's requirements.When the regenerated catalyst was changed in the entire SCR system and the ammonia escape concentration under each condition was about 2.5μg/g
the average denitration efficiency of the SCR system reached above 80%.Moreover