WU Shenglai, ZHAO Yongjian, GUO Rui. Discussion on correction calculation of pressure loss in steam and water system by the ASME PTC4-2008 method[J]. Thermal power generation, 2013, 42(12): 132-134.
WU Shenglai, ZHAO Yongjian, GUO Rui. Discussion on correction calculation of pressure loss in steam and water system by the ASME PTC4-2008 method[J]. Thermal power generation, 2013, 42(12): 132-134.DOI:
On the basis of tracing the deviation of the Bernoulli equations
the ASME PTC4-2008 correction calculation method for pressure loss in boiler steam and water system was considered improper.It proposed that fluid in the superheater
reheater and economizer should follow the law of energy balance.Suggestions that it is better not regard the pressure drop in superheater
reheater and economizer as the performance evaluation index were put forward.