WU Zhe, Zhou Duo, LI Zhouping. Effect mechanism of hydrogen displacement in generator on inner cooling water quality:research and application[J]. Thermal power generation, 2013, 42(10): 120-122.
WU Zhe, Zhou Duo, LI Zhouping. Effect mechanism of hydrogen displacement in generator on inner cooling water quality:research and application[J]. Thermal power generation, 2013, 42(10): 120-122.DOI:
发电机氢气泄漏对内冷水水质影响估算
摘要
对氢冷发电机氢气置换过程中残留在氢气中的CO2含量进行了估算
推算了随H2漏入内冷水系统的CO2对内冷水水质的影响
并结合实际机组取样检测结果以及氢气漏入内冷水系统的案例进行了分析。结果表明
当发电机设备存在缺陷时
氢气中CO2的存在将使内冷水pH值偏低
电导率升高
由此易引起铜线棒的腐蚀
需引起重视。
Abstract
The content of carbon dioxide remained in hydrogen during the hydrogen displacement in a hydrogen-cooled generator system was calculated roughly.Moreover
the effect of carbon dioxide escaped from hydrogen into the inner water cooling system on pH value of the inner cooling water was evaluated.On the basis of on-site sampling and detection
and combining with case study on hydrogen leaking into the inner water cooling system
the presence of carbon dioxide and its effect on the inner cooling water quality was demonstrated.Results showed that
when defects existed in the generator
the carbon dioxide in hydrogen would result in low pH value and high electrical conductivity of the inner cooling water