WANG Hongwei, FENG Yaofei, FENG Linkui, et al. Experimental study on peaking capability of a heating unit[J]. Thermal power generation, 2014, 43(4): 106-109.
WANG Hongwei, FENG Yaofei, FENG Linkui, et al. Experimental study on peaking capability of a heating unit[J]. Thermal power generation, 2014, 43(4): 106-109.DOI:
供热机组调峰性能试验
摘要
通过某∏T-140/165-130/15-2型供热机组的抽汽试验
绘制了机组在实际抽汽工况下新蒸汽流量与电功率的关系(工况图)
根据机组特性和实际热负荷
对工况图以及相应的试验数据进行分析并对不同抽汽流量下的功率进行修正
得出在不同热负荷下机组的调峰范围。研究结果表明:随着抽汽流量的增加
机组最小电功率随之增大
最大电功率先增大后减小;当抽气流量分别为60、120、180、240、300、360t/h时
机组的调峰范围分别为79.88、77.98、67.35、61.11、55.88、30.13 MW
即抽汽流量越大
机组的调峰范围越小。
Abstract
By steam extraction test on a∏T-140/165-130/15-2type heating unit
the diagram reflecting relationship between the new steam flow rate and electric power under actual condition was drawn.Moreover
according to the unit's characteristics and actual heat load
the above diagram and the corresponding test data were analyzed and the power at different extraction flow rates was revised.Thus the peak regulation range at different heat loads was obtained.The results show that:with an increase in extraction flow
the unit's minimum electric power rose
and the maximum electric power grew first and then decreased;when the extraction flow was 60t/h