FAN Yongsheng, ZHAO Zhenning. Diagnosis and comprehensive control of combustion problems occurred on a 330MW opposed-firing boiler[J]. Thermal power generation, 2014, 43(1): 128-132.
FAN Yongsheng, ZHAO Zhenning. Diagnosis and comprehensive control of combustion problems occurred on a 330MW opposed-firing boiler[J]. Thermal power generation, 2014, 43(1): 128-132.DOI:
investigation on problems occurred on a 330MW opposed-firing boiler was performed
such as air duct vibration
instable combustion and nozzle slagging.The incorrect working status of fans and improper air distribution mode and control logic which caused by large resistance in steam air heater were considered as the major reasons.After decreasing the resistance in steam air heater
revising the control logic
and optimizing the air distribution mode
the problems mentioned above were totally solved.Moreover
the boiler efficiency increased by 0.75%
the auxiliary power consumption rate decreased by 0.2%