ZHANG Liping, LI Kaituo, WANG Weifeng, et al. Operation optimization of an N-38000 dual-pressure condenser[J]. Thermal power generation, 2014, 43(7): 135-138.
ZHANG Liping, LI Kaituo, WANG Weifeng, et al. Operation optimization of an N-38000 dual-pressure condenser[J]. Thermal power generation, 2014, 43(7): 135-138.DOI:
The variable working conditions for both high and low pressure sides of an N-38000 type dual-pressure condenser was calculated
when this condenser was in single and dual water circulating pump operation
at different steam loads and cooling water inlet temperatures.On this basis
the equivalent heat drop method was applied to calculate the optimal inlet temperature of circulating water for suitching the single and dual circulating water pump
at different unit loads.The results show that
with the unit load of 40%
running single circulating water pump is more economical
while when the unit load is 60%
80% and 100%
the optimal inlet temperature of circulating water is 25.1℃