HU Sike, CAO Xueyuan, WANG Jiaqi. Application of cooperative regulation in variable load operation of power units[J]. Thermal power generation, 2014, 43(6): 41-45.
HU Sike, CAO Xueyuan, WANG Jiaqi. Application of cooperative regulation in variable load operation of power units[J]. Thermal power generation, 2014, 43(6): 41-45.DOI:
The variable speed adjustment for feed water pumps has well energy saving performance.However
whether the feed water pump can keep running with a high efficiency under variable load conditions has not been researched yet.Thus
suggestion that applying the cooperative regulation in large and medium-sized units under variable load conditions and with main steam turbine in sliding pressure operation and the boiler main feed water pump employing variable speed regulation was proposed.By taking a single set of tandem pumps in feed water system of a 200MW unit boiler as the example
calculation on this scheme was conducted.The results show that
when the cooperative regulation is put into service
the main feed water pump keeps running with the maximum efficiency
which is higher than both the feed water pump efficiency and booster pump efficiency when only the variable speed regulation is applied;the total power consumption of the pumps is lower than that when only the variable speed regulation is applied.Moreover
with a decrease in unit load
the energy saving ratio increases remarkable.It reaches about 58% when the unit load drops to 50%.