SONG Yubao, WANG Lele, JIN Lipeng, et al. Potential evaluation and service life prediction for SCR device based on field performance test[J]. Thermal power generation, 2015, 44(5): 39-44.
SONG Yubao, WANG Lele, JIN Lipeng, et al. Potential evaluation and service life prediction for SCR device based on field performance test[J]. Thermal power generation, 2015, 44(5): 39-44.DOI:
On the basis of conventional inspection method for single SCR catalyst element activity in laboratory
the NOxand ammonia escape concentration at inlet and outlet of the SCR device was measured during field performance test
by taking the multi-layer cascade catalyst in the SCR reactor as the research object.The de-NOxefficiency-ammonia slip method was used to evaluate the macroscopic SCR potential with the deNOxefficiency and ammonia slip measured from the field SCR performance test with the actual operating NH3/NO molar ratio less than 1.0.Field test results of 11 units show that the relative deviation of SCR potential in each unit with different NH3/NO molar ratios at full load ranges from-2.0%to 1.8%
indicating the field performance test data have well repeatability
which can reflect and evaluate the SCR device performance.Finally
by taking a down-fired 600 MW unit boiler as the example
the SCR performance degradation function over time was regressed from the SCR potential measured at different time and then used to adding or replacing the catalyst layer.