LI Jun, DENG Xiaoming. Improvement of air intake system in M701F gas turbines[J]. Thermal power generation, 2015, 44(7): 121-124.DOI:
M701F燃气轮机进气过滤系统改进
摘要
为改善F级燃气轮机(燃机)进气过滤系统对粒径小于0.4μm微小颗粒的捕捉效果
对燃机进气过滤系统进行改进
在维持两级过滤设计不变的情况下将空气过滤器的过滤等级提高到H11级。进气过滤系统改进后
第1级粗滤采用化纤多层复合无纺布滤材
过滤等级为F5
适应性较好
不容易发生粘性颗粒堵塞;第2级HEPA精滤的滤材为过滤等级H11的高效玻纤材料
对0.4μm粒径的初始过滤效率达到96%以上
比旧型过滤器过滤效率提升了59%。改进后现场使用效果理想
机组效率得到提升。
Abstract
To enhance the F class gas turbine air intake system's capture ability on tiny particles of 0.4μm or lower
the air filter of the turbine air intake system was improved.The filtering level was enhanced to H11 on premise of keeping two-stage filter design.In the first stage of coarse filter
multilayer chemical fiber containing nonwoven filter was adopted
with filter level of F5
the air inlet filtering system had better adaptability and was not easy to be clogged by sticky particles.In the second stage of fine HEPA filter
the efficient glass-fiber was adopted
with filter level of H11
its initial filter efficiency for particles of 0.4μm reached 96%
about 59% higher than that of the old type filter.After optimization
the field application effect can meet the relative requirements and the unit efficiency was increased.