ZHOU Yan, LIU Feng, WANG Li, et al. Entransy dissipation based performance analysis for solar chimney power plant system with vertical collectors[J]. Thermal power generation, 2015, 44(9): 48-51.
ZHOU Yan, LIU Feng, WANG Li, et al. Entransy dissipation based performance analysis for solar chimney power plant system with vertical collectors[J]. Thermal power generation, 2015, 44(9): 48-51.DOI:
On the basis of the principle of entransy dissipation and the principle of minimum thermal resistance in heat transfer theory
the expression of entransy dissipation rate of the solar chimney power plant system with vertical collectors was derived and the heat transfer performance of this system was analyzed.The results show that
the structure dimensions of the chimney are the main factors affecting the performance of the solar chimney power plant system with vertical collectors.However
the height and width of the solar chimney are limited by the height and space between the windows of high buildings
thus the thickness of the solar chimney is the foremost factor to decrease the entransy dissipation of the solar power plant system.Under conditions with constant chimney height and width
the thermal resistance of entransy dissipation of the solar system reached the minimum when the solar chimney thickness was 0.959 8m
indicating the performance of the system achieved the optimum.