CHEN Shixin, FAN Zengshe, YAN Xiaohui, et al. Cold end joint operation technology for damp unit and direct air cooling unit[J]. Thermal power generation, 2015, 44(11): 90-93.
CHEN Shixin, FAN Zengshe, YAN Xiaohui, et al. Cold end joint operation technology for damp unit and direct air cooling unit[J]. Thermal power generation, 2015, 44(11): 90-93.DOI:
For the damp and direct air cooling units constructed during different periods in the same power plant in northern areas of China
the unit system operation mode was changed
and a kind of cold end joint operation system was put forward.This system was applied in a power plant owning two subcritical600 MW coal-fired damp units and two subcritical 600 MW coal-fied direct air cooling units.The results show that
after the unit cold end joint operation
the units can save standard coal of 3.49g/(kW·h)in summer
so the high back pressure and decreasing output problems of the direct air cooling unit in summer was effectively solved.Under rated conditions
the units can save standard coal of 2.97g/(kW·h)
and under any operation conditions
the heat consumption rate of both air cooling units and damp units can be decreased and the thermal efficiency of the units can be enhanced.The investment recovery period of this method is about 2years.