DAI Xin, TIAN Li, PAN Zhenbo, et al. An on-line measurement method of trace chlorine ion and its application in power plants[J]. Thermal power generation, 2016, 45(2): 81-85.
DAI Xin, TIAN Li, PAN Zhenbo, et al. An on-line measurement method of trace chlorine ion and its application in power plants[J]. Thermal power generation, 2016, 45(2): 81-85.DOI:
The application status of current detection method for trace chloride ion at home and aboard was summarized.On this basis
this paper improved the spectrophotometric method and proposed an online measurement method for trace chloride ion in water vapor system of power stations
which modifies the formula of chromogenic agent and adds the concentration system and waste liquid treatment device.The chromogenic agent consists of a variety of additives and is a water soluble medicament with low toxicity.This online method can detect chloride ions with concentration range from 0μg/L to 1 000μg/L.Application of this method on chloride ions detection for a 300 MW
600 MW and 1 000 MW unit shows that
the minimum detection limit of this trace chloride ion online measuring method can reach 0.2μg/L
the relative deviation of the measurement results is small and has good repeatability and accuracy
indicating this method can be applied in the monitoring of chlorine ion concentration in the water vapor system of power plants.