HUA Xiaoyu, WANG Ruikun, QIU Lichun, et al. Anti-balancing efficiency and its uncertainty analysis of boiler burning mixed coal according to ASME and GB standard[J]. Thermal power generation, 2016, 45(3): 34-40.
HUA Xiaoyu, WANG Ruikun, QIU Lichun, et al. Anti-balancing efficiency and its uncertainty analysis of boiler burning mixed coal according to ASME and GB standard[J]. Thermal power generation, 2016, 45(3): 34-40.DOI:
To find out the adaptability of the boiler and its auxiliary equipments in a power plant to coal blending
and provide operational experiences for the future
the Australian coal was mixed and used in a power plant boiler with domestic Youhun coal.The anti-balancing efficiency of the boiler was calculated according to two standards:the American Society of Mechanical Engineers(ASME)standrd and National Standard of China(GB).The uncertainty of the boiler efficiency was also analyzed using the above two standards based on seven main influencing parameters of the boiler efficiency.The results showed that
by ASME standrd
the boiler efficiency was 93.73%and 93.83%respectively for case 1(burning Youhun coal solely)and case 2(m(Australian coal)∶m(Youhun coal)=1∶1).While by GB
the boiler efficiency was93.10% and 93.28%respectively for the case 1and 2.Mixing Australian coal increased the boiler efficiency slightly.By ASME standrd
the uncertainty of the boiler efficiency U95(η)was 0.210% and 0.218%for the case 1and 2.While by GB
the uncertainty of the boiler efficiency U95(η)was 0.244% and 0.256%for the case 1and 2.The uncertainty of the boiler efficiency was very small
suggesting the quality of boiler efficiency measurement was very high.